Measurement of G Using a Cryogenic Torsion Pendulum: Post-2008 Analysis Review
1 Department of Physics and Astronomy, University of California Irvine, Irvine, CA 92697-4575, USA
2 ExoAnalytic Solutions Inc., Mission Viejo, CA 92692, USA
3 MongoDB, New York, NY 10036, USA
a e-mail: rdnewman@uci.edu
Published online: 11 June 2014
A measurement of G by our University of California, Irvine (UCI) team was reported at the 2008 Conference on Precision Electromagnetic Measurements (CPEM) [1]. This work has not yet been published; work continues to review and refine analysis of data from that measurement. We present in this paper the analysis and results of the measurement as it stood at the time of the 2008 conference, and discuss the analysis review under way. Our G measurement was conducted “blind”, keeping the exact value of the source mass hidden until just before the conference presentation.
© Owned by the authors, published by EDP Sciences, 2014
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.