https://doi.org/10.1051/epjconf/20147700014
Inductive voltage divider calibration with sampling method
Federal Institute of Metrology METAS, Lindenweg 50, 3003 Bern-Wabern, Switzerland
a Corresponding author: david.corminboeuf@metas.ch
Published online: 19 August 2014
This paper presents an automatic system developed at METAS for the calibration of inductive voltage dividers (IVD). The used method is primary for the n/10 ratio. With the described improvements, the calibration of IVDs has been made easier, faster and more reproducible than with the manual system used before. The uncertainties which can be reached with this new system are 28·10-9 for the in phase and quadrature parts at a frequency of 1 kHz.
© Owned by the authors, published by EDP Sciences, 2014