https://doi.org/10.1051/epjconf/201919600022
Critical heat flux in a closed two-phase thermosyphon
1 National Research Tomsk Polytechnic University, 634050 Tomsk, Russia
2 Institute of Thermophysics Siberian Branch, Russian Academy of Sciences, Lavrentiev Ave. 1, Novosibirsk, 630090, Russian Federation
* Corresponding author: kop.tpu@gmail.com
Published online: 14 January 2019
A closed two-phase thermosyphon experimental setup with the possibility of recording the coolant and its vapors temperatures was developed. We proved the use of the V. M. Borishansky and S. S. Kutateladze correlations for the determination of the critical heat flux in closed two-phase thermosyphons with the ratio of their internal diameter to the length of the heat supply zone in the range of 1 < dBhym / Lu < 2.
© The Authors, published by EDP Sciences, 2019
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.