https://doi.org/10.1051/epjconf/201921302022
Determination of the uncertainty of mass flow measurement using the orifice for different values of the Reynolds number
1
Gdańsk University of Technology, Faculty of Electrical and Control Engineering, 80-233 Gdańsk, Poland
2
The President Stanisław Wojciechowski State University of Applied Sciences in Kalisz, Polytechnic Faculty, 62-800 Kalisz, Poland
3
Rzeszów University of Technology, Faculty of Electrical and Computer Engineering, 35-959 Rzeszów, Poland
4
AGH University of Science and Technology, Faculty of Geology, Geophysics and Environmental Protection, 30-059 Kraków, Poland
* Corresponding author: anna.golijanek-jedrzejczyk@pg.edu.pl
Published online: 28 June 2019
Standard orifice flowmeters are widely used in the chemical and energy industry. Therefore, it is essential to know how accurate the measurements made with these instruments are. The paper presents an estimation of measurement uncertainty of a liquid mass flow using the orifice plate. The authors will present the influence of ranges of the Reynolds number on the estimated uncertainty, obtained on the basis of simulation and laboratory experiments. The research was conducted for the central orifice in the Reynolds number 8,000 < Re < 21,000. The results of estimating the extended uncertainty of the measurement of water flow using simulation and experimental method, are convergent. The maximum difference in the extended uncertainty values of flow measurement for the simulation and experiment was 0.04.10-3 kg/s.
© The Authors, published by EDP Sciences, 2019
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.