A Study on the Establishment of Radiation Dose Estimation Procedure for Accumulated Radioactive Ions for RAON ISOL System
1 Department of Nuclear Engineering, 04763 Hanyang University, Korea
2 Facility Construction & Infrastructure Division, Rare Isotope Science Project, 34047 Institute for Basic Science, Korea
a Corresponding author: chshin@nural.hanyang.ac.kr
Published online: 25 September 2017
For purposes of various experiments, RAON heavy ion accelerator facility has been designed in Korea. ISOL is one system of RAON accelerators to generate and separate rare isotopes. Radioactive ions generated from target-proton reactions are separated and accumulated at separation devices. The accumulated isotopes release the gamma radiations; therefore, the radiation safety must be clearly estimated. In this study, a process to evaluate radiations from the accumulated ions was proposed by modifying FISPACT code. The proposed process was validated by comparing a solution of single element decay problem. Using the process, a preliminary study for radiation doses were performed in a virtual separation devise.